Sabine Van Huffel, Manfred Kessler and Alphons Krug (Institute of Physiology and Cardiology, University of Erlangen-Nürnberg, Germany)
Improved models based on Kubelka-Munk theory, as well as improved algorithms, for the quantification of chromophore concentrations in tissues based on optical multi-wavelength measurements, have been presented.
By means of principal component analysis (PCA) and canonical
correlation analysis (CCA) on measurement spectra recorded in isolated
perfused rat liver (see figure),
it is shown that the currently used model
describing mainly the contributions of Hb and HbO
should be
refined by including a component describing the wavelength-dependent
absorption characteristics of haemoglobin-free liver. If this is the
case, the inclusion of a constant term in the model function is no
longer needed. The usefulness of PCA and CCA for model validation is
investigated and proven by many examples. It is shown how PCA is able
to detect the number of independent components with variable
contribution. A subsequent CCA points out these components, which
should be included in the model function.
Furthermore, three different methods for estimating the model parameters have been presented: a nonlinear least squares (NLLS) algorithm, an ordinary least squares (LS) algorithm and a mixed LS-total least squares algorithm wLS-TLS with appropriate weights. The ordinary LS algorithm is computationally most attractive but induces a too large bias in the parameter estimates which becomes dominant at low signal-to-noise ratio. In contrast, the NLLS algorithm computes the most accurate estimates due to a small bias but its computational load is 10 to 30 times (depending on the number of iterations used) higher than that of LS and wLS-TLS. The wLS-TLS algorithm offers the best compromise since it is almost as efficient as ordinary LS and almost as accurate as NLLS fitting.
It should be noted that this analysis was performed on optical measurements recorded in the visible range. The same analysis can be performed on the near-infrared measurement data and is currently being executed. Similar results are expected but, due to the lower signal-to-noise ratio, the overall accuracy of the computed chromophore concentrations will be reduced.
Figure: 67 absorption-to-scattering spectra of isolated rat liver
perfused with Hb increasing from
0.24 to 0.58 g/dl and O
influx constant at 95%.