NeoGuard - NeoGuard: a neonatal EEG monitor with real-time, bedside data visualization and automated decision support

From 01-09-2012 to 30-06-2016

Description

Summary:

The main goal of the NeoGuard project is to build a decision supportive tool for the diagnosis and management of neonatal seizures and abnormal background patterns in term infants with encephalopathy. The main task is to insert the qualified expertise regarding electroencephalographic (EEG) diagnosis in term infants into an instrument that can be easily and reliably used by the neonatologist in the NICU and the pediatrician in the medium care setting. The rationale of this project is thus to address the main problems with infant EEG at this moment. These problems are the application of the EEG electrodes, manual (subjective) interpretation of the signals and the around the clock availability of EEG experts being too difficult and too time consuming for routine use.

 

Hereto, the project wants to meet the following goals:

1.    To produce an EEG instrument for continuous brain monitoring, NeoGuard, enabling automated detection of neonatal seizures and abnormalities in the EEG background  pattern. The neonatal nurse or clinician should be able to use the instrument after a short instruction workshop,  although verifying automated detections with the raw EEG signal by a supervising expert clinical neurophysiologist will remain preferable.

2.    To validate the automated seizure detection program and to validate the background classification program by comparing it with expert EEG interpretation and the extent of brain damage on MRI and psychomotor development of the patients. This will happen in the neonatal intensive care units in Leuven, Antwerp and Rotterdam.

 

The clinical study will focus on the term infant with encephalopathy. Two presenting pathologies will be studied:

1.    Hypoxic-ischemic encephalopathy: term babies born with an umbilical pH of less than 7,1 ; an Apgar score at 5 minutes of less than 6 and a Thompson score of more than 4. A Thompson score of more than 4 (instead of 6) is chosen in order to include the majority of patients with encephalopathy.

2.    Term babies with seizures. We will include all babies with a clinical diagnosis of neonatal seizures. Later in the study, patients with different pathologies (metabolic disease, cerebral bleeding, cerebral infarction) can be grouped and studied differently.

3.     

Once the project is finished we would like to provide every major neonatal unit in Flanders (Leuven, Antwerp, Brussels) as well as the EMC Rotterdam with a prototype of the NeoGuard. After a validation study, also large maternity units will be provided with a NeoGuard, coupled with one or more  workshops.

Team

  • Sabine Van Huffel, Co-promoter
  • Bob Puers, Co-promoter (External)
  • N. N., Co-promoter (External)
  • N. N., Co-promoter (External)
  • N. N., Co-promoter (External)
  • Gunnar Naulaers, Promoter (External)

Financing

Funding: IWT - Agentschap voor Innovatie door Wetenschap en Technologie 

Program/Grant Type: IWT TBM - VLAIO TBM Projects Applied Biomedical Research with a Primary Social finality